Liquid Chromatography Polymer Testing Application Summary Molecular weight distribution measurements are needed here because polymer molecules are different than the molecules in many other ordinary materials and chemicals. For ordinary compounds, all of the molecules are identical, with the same molecular weight and unique properties such as melting and boiling points, and vapor pressure. Changing the chemical structure, and thus molecular weight, produces an entirely new compound with different properties. But polymers are different. Polymer molecules consist of a number of smaller molecules, or monomers, reacted together end-to-end to form a chain of repeat units. A polymer sample contains a mixture of molecules, with molecular weights differing by even numbers of repeat units. The molecular weights of individual chains in a statistical sample typically follow a bell curve (or another) distribution. The test setup for determining the distribution requires a chromatography system and a means to automatically run a large number of samples. The test system controls pumps, solenoid valves, and an automatic sampler while simultaneously collecting the data from the output of the chromatograph detector and sending it to a desktop computer. The controller and data collection system must be highly reliable, flexible, easy to set up, and adaptable to a wide variety of instrument configurations. Potential Solution IOtechs Solution I was able to program the system to load a list of samples to be run, command the DaqBook to send a TTL-level signal to the automatic sampler to execute the programmed injection sequence, and monitor the signal in the ADC while the sample is going through," says Caflisch. "The IOtech TTL logic circuits also operate a solenoid valve that recycles the solvent back to the reservoir when polymer is not eluting from the column, and shut the system down when all of the samples have run. The detector signal changes slowly enough that it is sufficient to record only one point per second. In order to eliminate any 60-Hz noise that might enter the system the ADC is scanned at 1000 Hz and each data point is averaged over sixteen scans. Caflisch uses two eight-channel DaqBooks, each of which controls four chromatographs. Each polymer sample to be analyzed is first dissolved and this solution is loaded into the automatic sampler, which injects a small amount of it into the flowing solvent stream of the chromatograph on command. It then passes through an SEC column, a tube filled with beads of cross-linked polystyrene. The beads contain small pores of various sizes in a range similar to the dimensions of the polymer molecules in solution. On their journey from input to output, the polymer molecules diffuse into and out of the pores. Because the smaller molecules can fit into more of the pores, they spend relatively more time there and thus travel more slowly through the column than the larger ones. Therefore, the polymer molecules are separated by molecular weight, with the larger ones eluting from the column before the smaller. The detector signal is proportional to the concentration of polymer coming out at a given time so the DaqBook can plot the concentration of polymer molecules exiting vs. time. A calibration curve is used to calculate the molecular weight from elution time and convert the time-base plot into molecular weight on the x-axis and the mass fraction with a particular weight on the y-axis. Conclusion |